DC-Bearing
|
Bearing capacity analysis acc. to Eurocode 7, Eurocode 8 / DIN 1054:2010 and 2005 / DIN 4017 / SIA 267 / OENORM B 4435-2 / Terzaghi / Brinch Hansen |
|
|
DC-Settle |
Analysis of settlement of any number of foundations acc. to Eurocode 7 / DIN 1054:2010 and 2005 / DIN 4019 / SIA 267 |
|
|
DC-Footing |
Analysis of footings (rectangular, strip, circular footings) with all foundation engineering checks and optimization acc. to Eurocode 7, Eurocode 8 / DIN 1054:2010 and 2005 / SIA 267 |
|
|
DC-Footing/Pylon |
Analysis of fixed pylon footings acc. to Steckner, Eurocode 7 / DIN 1054:2010 and 2005 / SIA 267 |
|
|
DC-Slope |
Base and slope failure acc. to Eurocode 7, Eurocode 8 / DIN 1054:2010 and 2005 / DIN 4084 / SIA 267 (Krey-Bishop/Janbu)
|
|
|
|
Reinforced earth with geosynthetics, acc. to Eurocode 7, Еurocode 8 / DIN 1054:2010 and 2005 / SIA 267 / EBGEO 2010 |
|
|
|
Analysis of gabions and supporting structures of layered blocks and concrete stack stones acc. to the bulletin of FGSV and Eurocode 7, Еurocode 8 / DIN 1054:2010 and 2005 / SIA 267 |
|
|
|
Analysis of cantilever walls acc. to Eurocode 7, Eurocode 8 / DIN 1054:2010 and 2005 / DIN 4085 / SIA 267. Design acc. to EC 2 / DIN EN 1992 / DIN 1045 / DIN 1045-1 / SIA 262 / OENORM B 1992 / OENORM B 4700 / BS 8110 / IS 456
|
|
|
|
Analysis of foundation pit walls (bore pile, diaphragm, sheet piling, girder plank walls, MIP) acc. to Eurocode 7 / DIN 1054:2010 and 2005 / DIN 4085 / SIA 267 / British Standard BS 8002 / EAU 2004 / EAB 2006. Verification of the transfer of vertical forces acc. to EAB, R 9, R 84 and R 85. Analysis with earthquake loads available acc. to Eurocode 8-5 / Mononobe-Okabe. |
|
|
|
Design of all wall types, infilling (wood, concrete, pile infilling), anchors and booms (Eurocode 2 / 3, DIN EN 1992 / 1993, DIN 1045-1 / 18800, OENORM B 1992 / 1993, SIA 262 / 263, OENORM B 4700, BS 8110 / 5950, IS 456 / 800) |
|
|
DC-Crack |
New! Serviceability verifications / Crack width limitation. Option for DC-Pit available only together with DC-Pit Dimensioning. |
|
|
DC-Reinforcement |
New! Graduation of reinforcement over envelope line of tensile force. Option for DC-Pit available only together with DC-Pit Dimensioning. |
|
|
|
Soil nailing incl. wall design acc. to Eurocode 7 / DIN 1054:2010 and 2005 / SIA 267 / approvals
|
|
|
|
Building underpinnings and retaining walls acc. to EC 7 / DIN 1054:2005 / SIA 267 / OENORM B 1997-1-1, earthquake load analysis acc. to Eurocode 8-5 / Mononobe-Okabe
|
|
|
Underpinning Optimization |
Optimization of the wall thickness and anchor forces. |
|
|
|
Integrated foundation engineering: from the plan to the analysis |
|
|
|
Option for the program DC-Integra: 3D display of foundation pits with exact wall geometry. Automatic generation of slope intersections. Arbitrary sections through the ground model with display of the soil layer levels incl. color and symbols. New: IFC interface |
|
|
|
Calculation of the excavation volumes and masses for complex foundation pits at the push of a button. Calculation of the excavation volume, including swell factor per soil layer and total |
|
|
DC-Integra3D/Pipeworks |
Option for the program DC-Integra with DC-Integra 3D: display of sewer pipes, water, gas, electricity, district heat, cable trench in the 3D model |
|
|
DC-Integra3D/Anchors |
3D display and collision check of anchors: check for collision with anchors, pipeworks and buildings. Collision check of spreading and horizontally deviated anchors. Labeling of the critical distances for a better overview
|
|
|
DC-Pile |
Design of bored, driven, micro piles acc. to Eurocode 7 / DIN 1054:2010 and 2005 / Rec. on Piles / DIN 4014 / DIN 4026 / DIN 4128 / SIA 267 / OENORM B 4440 / BS 8004 New: analysis acc. to OENORM B 1997-1-3 |
|
|
DC-Pile/Npw |
Design of piles in slopes, e.g. for noise protection walls, acc. to ZTV-Lsw 06 / approach by Vogt |
|
|
DC-Pilegroup (small) |
Small program version: analysis and design of pile groups with head plate acc. to Eurocode 7 / DIN 1054:2010 and 2005 / Rec. on Piles / SIA 267 / OENORM B 1997-1-1 / BS 8004 |
|
|
|
Large program version: analysis and design of Combined Pile Raft Foundations (CPRF) acc. to Eurocode 7 / DIN 1054:2010 and 2005 / Rec. on Piles / SIA 267 / OENORM B 1997-1-1 / BS 8004 |
|
|
DC-Vibro |
Analysis of vibrocompaction (stone columns) acc. to Priebe, Eurocode 7 / DIN 1054:2010 and 2005 / SIA 267 more>>
|
|
|
DC-Dewatering |
Ground water lowering with multi-well installations |
|
|
DC-Infilt |
Analysis of infiltrations |
|
|
DC-Lamella |
Stability of diaphragm wall lamellae acc. DIN 4126 and Eurocode 7 New: Determination of the supporting force Sk alternatively with the more exact method acc. to fig. 3b of DIN 4126:2013 |
|
Packages:
|
|
Foundation 1 |
DC-Slope, DC-Pit with Dimensioning and DC-Nail |
|
Foundation 2 |
DC-Slope, DC-Cantilever, DC-Pit with Dimensioning, DC-Nail, DC-Underpinning, DC-Pile |
|
Foundation 3 |
DC-Bearing, DC-Settle, DC-Footing, DC-Footing/Pylon, DC-Slope, DC-Geotex, DC-Gabion, DC-Cantilever, DC-Pit with Dimensioning, DC-Nail, DC-Underpinning with Optimization, DC-Integra + 3D + Volume + Pipeworks + Anchor, DC-Pile, DC-Pile/Npw, DC-Pilegroup CPRF, DC-Vibro, DC-Dewatering, DC-Infilt, DC-Lamella, DC-Crack, DC-Reinforcement |
|